Professional Writers
We assemble our team by selectively choosing highly skilled writers, each boasting specialized knowledge in specific subject areas and a robust background in academic writing
Fill the order form details - writing instructions guides, and get your paper done.
Posted: February 26th, 2022
Case 3
Procedure: Dual Chamber Implantable Cardioverter Defibrillator (ICD) Implantation Pre-Procedure Diagnosis: Hypertrophic Cardiomyopathy, NSVT, SSS, Near Syncope Procedure: The patient was brought to the Electrophysiology Lab in the fasting state and continuous electrocardiographic monitoring was instituted. Anesthesia was performed by Dr Kiss and will be dictated separately by him. The left subclavicular fossa was prepped and draped in the usual sterile fashion and 1% lidocaine was instilled for local anesthesia. The incision was made and the dissection was carried down to the level of the pectoralis major fascia where a subcutaneous pocket was formed using blunt dissection. The axillary vein was entered with a Micropuncture thin walled needle without difficulty at two separate locations, guided by ultrasound, and guide wires were advanced into the central venous circulation. Using the guide wires and two introducer sheaths, an ICD electrode was advanced to the right ventricular septum, and a pacing electrode was advanced to the right atrial appendage under fluoroscopic guidance. Each electrode was anchored to the underlying pectoralis major fascia with a single stitch of 2-0 non-absorbable suture. These leads were attached to a dual chamber ICD which was placed in the previously formed pocket with electrodes situated beneath it after the pocket had been flushed with saline solution. The ventricular electrode is a Medtronic Model # 6935M62 (Serial # TDL515430V). This is a bipolar, steroid-tipped, active fixation lead. The R wave was 10 mV, the pacing impedance was 600 Ohms, and the ventricular capture threshold was 0.75 V @ 0.5 ms. The HVB impedance was 76. There was no diaphragmatic pacing at 10 V. The atrial electrode is a Medtronic Model # 5076 (Serial # PJN8450680). This is a bipolar, steroid-tipped, active fixation lead. The P wave was 1.3 mV, the pacing impedance was 650 Ohms, and the atrial capture threshold was 1.3 V @ 0.5 ms. There was no diaphragmatic pacing at 10 V. The ICD pulse generator is a Medtronic Evera MRI DR. Model # DDMB1D4, Serial # PFZ622773S. This device is placed in the subcutaneous location. No defibrillation threshold testing was performed. The wound was closed with a running stitch of 3-O absorbable suture and the skin was closed with a running stitch of 4-O absorbable suture. Topical skin adhesive was placed over the incision. The patient tolerated the procedure well.
You Want Quality and That’s What We Deliver
We assemble our team by selectively choosing highly skilled writers, each boasting specialized knowledge in specific subject areas and a robust background in academic writing
Our service is committed to delivering the finest writers at the most competitive rates, ensuring that affordability is balanced with uncompromising quality. Our pricing strategy is designed to be both fair and reasonable, standing out favorably against other writing services in the market.
Rest assured, you'll never receive a product tainted by plagiarism or AI-generated content. Each paper is research-written by human writers, followed by a rigorous scanning process of the final draft before it's delivered to you, ensuring the content is entirely original and maintaining our unwavering commitment to providing plagiarism-free work.
When you decide to place an order with Nurscola, here is what happens: