Introduction: The ion-selective electrode used was made up of a silver/silver chloride reference electrode and a glass electrode. The pH of the electrochemical cell is determined by monitoring the electrical potential difference between the half-cells. The glass electrode is an ion-selective electrode (ISE), which only responds to the hydronium ion concentration/activity in a solution under a large range of conditions.
In this experiment, we are measuring the fluoride ion concentration, which means our electrode responds to fluoride ion concentrations.
Standard Solutions
Concentration (M)
Potential (mV)
0. 9967 x 10-6
15. 0
0. 9967 x 10-5
1. 4
0. 9967 x 10-4
-42.
0. 9967 x 10-3
-101. 1
0. 9967 x 10-2
-160. 8
0. 9967 x 10-1
-219. 0
Unknown #6 was used for this lab group. It produced a potential difference of -196. 8 mV. This was then used in the equation derived from our standard solutions and found to have a [F-] = 0. 0618 M. Preparation of the toothpaste sample was done by a sonicator. Then, the electrical potential difference was measured again, just as in the standard solutions and unknowns. It was found to have a potential of -85. 6 mV.
Inserted into the equation, [F-] = 3. 31 x 10-4 M.
Calculations: See attached sheets.
Results: Toothpaste [F-] = 3. 31 x 10-4 M
Unknown #6 [F-] = 0. 0618 M Label Value in Toothpaste 0. 15% w/v Calculated Value in Toothpaste 0. 8 mg / g 0. 8 mg/g converted to w/v (g/100 mL) is approximately 0. 1144% w/v. In comparison with the label, the calculated error is found to be about -24%. A potential source of error could be found in the method of dissolving the toothpaste. There were a lot of bubbles formed, thus allowing for a greater possibility of misreported volumes of solution. Also, the pH / V meter had difficulty settling on values during the standard measurements, which would alter the regression line. The ISAB seemed to work better with stronger concentrations of [F-], as the regression line fit better toward the latter part of the plot. However, the pH region seemed to be less important than the [F-] concentration.
You Want Quality and That’s What We Deliver
We assemble our team by selectively choosing highly skilled writers, each boasting specialized knowledge in specific subject areas and a robust background in academic writing
Our service is committed to delivering the finest writers at the most competitive rates, ensuring that affordability is balanced with uncompromising quality. Our pricing strategy is designed to be both fair and reasonable, standing out favorably against other writing services in the market.
Rest assured, you'll never receive a product tainted by plagiarism or AI-generated content. Each paper is research-written by human writers, followed by a rigorous scanning process of the final draft before it's delivered to you, ensuring the content is entirely original and maintaining our unwavering commitment to providing plagiarism-free work.
When you decide to place an order with Nurscola, here is what happens: